Block of Flats Security & HMOs: The Complete UK Installer's Guide 2026

Securing a block of flats or a house in multiple occupation (HMO) is a different job from fitting cameras to a single home. There are several households behind one front door, a landlord or freeholder who carries legal duties for the common parts, tenants who change every year, and a fire strategy that the security kit must never undermine. This guide is the UK installer’s reference for block of flats security and HMO security: who is responsible for what, the fire and data protection rules that shape the design, where communal CCTV belongs, door entry and fob access for flats, fire alarm grades for HMOs, fire door checks, leak detection and Wi-Fi for shared houses — with three reference builds using the Hikvision, HiLook, Ajax and Reyee kit we stock in Leicester.

What this guide covers

  • Why multi-occupancy buildings need a different security design
  • Who the Responsible Person is, and what landlords, freeholders and managing agents must do
  • The rules at a glance: Fire Safety (England) Regulations 2022, smoke and CO alarm rules, HMO licensing, Scotland’s interlinked alarm standard and the ICO
  • Communal CCTV that respects tenants’ privacy, with a zone-by-zone camera plan
  • Recording, retention and handling requests for footage
  • Video door entry for flats: IP modular, 2-wire HD retrofit and small-HMO door stations
  • Fob access control with fail-safe locks
  • Stay put vs communal fire alarms, HMO fire alarm grades and where Ajax wireless alarms fit
  • Fire door checks, leak detection, void property protection and HMO Wi-Fi
  • Three reference builds and eight installer FAQs
Block of flats and HMO security guide for UK installers with Hikvision modular door station, LiveGuard turret and Ajax FireProtect 2

Why flats and HMOs are a different security job

A multi-occupancy building has shared spaces that nobody owns individually, so security has to protect every household at once without letting one household watch another. That single fact drives most of the design decisions in this guide.

Three differences matter on site. First, the people: residents come and go, sub-letting and lost fobs are routine, and the person paying for the system (the landlord, freeholder or residents’ management company) usually does not live there. Second, the law: fire safety duties for the common parts sit with a named Responsible Person, HMO licences add conditions of their own, and any camera that sees a corridor or car park brings data protection law with it. Third, the fire strategy: most purpose-built blocks are designed so that residents of a flat that is not on fire can stay where they are, and a badly specified alarm or lock can break that strategy.

Get those three right and the same system also deals with the problems managing agents actually phone installers about: tailgating at the main door, parcel theft from the lobby, fly-tipping in the bin store, bike theft, e-scooters charging in corridors, damage in the car park and the flat upstairs flooding the flat below.

Who is responsible: landlord, freeholder or managing agent?

The Responsible Person for fire safety in the common parts is whoever owns or controls them — usually the freeholder, a residents’ management company or the landlord of an HMO, often acting through a managing agent. Your quote, your commissioning records and your handover pack should be addressed to that person.

The government’s fire door guidance names both building owners such as freeholders and other people in control of the premises, such as managing agents, as Responsible Persons, and says a breach of the 2022 Regulations is a criminal offence if it puts anyone at risk of death or serious injury in a fire (GOV.UK: Fire Safety (England) Regulations 2022 fire door guidance). The same person will normally be the data controller for any communal CCTV, which means they decide what is recorded and why; a managing agent who runs the system for them is acting on their behalf.

For a single-let flat the picture is simpler: the landlord is responsible for the alarms inside the flat, and the freeholder for the common parts. For an HMO, the licence holder is responsible for both. Before you design anything, ask who will sign off the fire risk assessment and who will own the CCTV recordings — and write both names on the job sheet.

The rules at a glance

Five sets of rules shape a block of flats or HMO job: the Fire Safety Order and the 2022 Regulations for the common parts, the smoke and carbon monoxide alarm rules inside rented homes, HMO licensing, Scotland’s interlinked alarm standard and UK data protection law for any camera that sees a shared space.

RuleWhat it requiresWhat the installer delivers
Fire Safety (England) Regulations 2022In force since 23 January 2023 for buildings with two or more homes and common parts; fire door information for every resident; quarterly communal door checks and annual flat door checks where the top storey is above 11 mSelf-closing doors that still close with access control fitted; hold-open devices only on smoke detection; door hardware that does not stop a fire door shutting
Smoke and CO alarm rules (England)A smoke alarm on every storey used as living accommodation and a CO alarm in rooms with a fixed combustion appliance (not gas cookers), for private and social landlordsAlarms on every level of each flat, CO alarms next to boilers and stoves, test records at the start of each tenancy
HMO licensing and LACORS / BS 5839-6Licence conditions set by the council, usually based on LACORS guidance and BS 5839-6 grades and categoriesThe grade and category the council asks for — often mains-powered Grade D1 — plus fire doors and a protected escape route
Scotland tolerable standardInterlinked, ceiling-mounted smoke and heat alarms in every home since February 2022, plus CO detection where there is a carbon-fuelled applianceInterlinked alarms, which can be sealed long-life battery or mains-powered
UK GDPR / ICOAny camera that captures a communal space is covered by data protection lawCameras aimed at shared areas only, privacy masks, signage, set retention and a way to export clips for requests

The sources for each row are linked in the sections below. Wales has its own renting rules under the Renting Homes (Wales) Act and Northern Ireland has separate legislation, so check the local position before you quote outside England and Scotland.

Communal CCTV and data protection: what landlords must do

CCTV in the common parts of a block is lawful and common, but because it records residents and visitors in shared spaces, data protection law applies in full. The landlord or freeholder must be able to explain why each camera is there and show that it records no more than it needs to.

The ICO’s guidance is clear that once a camera captures someone else’s property, a public area or a communal space, data protection law applies. The owner must have a clear reason, avoid capturing more than they need, display signs, provide recordings to people who ask for footage of themselves, delete footage regularly or automatically and stop recording a person who objects unless there is a legitimate reason to carry on; requests should usually be answered within one calendar month (ICO: Home CCTV systems). A landlord or managing agent running cameras across a whole building is operating as an organisation, so the ICO’s guidance for organisations is the fuller reference (ICO video surveillance guidance).

The same ICO guidance covers the tenant who fits a smart doorbell on a flat door that also looks down the shared corridor: the ICO says that tenant is likely to have a legitimate reason, but still has to follow the data protection rules. Landlords increasingly write a CCTV and doorbell clause into tenancy agreements so that everyone knows where they stand. For the installer, the practical rules are simple:

  • Point cameras at shared spaces only — never into a flat, through a window or onto a private balcony or garden.
  • Use privacy masks wherever a view passes a flat door, a neighbour’s window or the street.
  • Turn audio recording off unless the landlord has a documented reason for it.
  • Fit signs at every entrance and covered area naming the operator.
  • Give each person who reviews footage their own login, and keep admin access with the landlord or agent.

Our UK GDPR and CCTV guide covers the operator’s wider duties, including privacy notices and impact assessments.

A camera plan for a block of flats

Communal CCTV should cover the routes into the building and the places where trouble starts — entrances, the lobby, bin and bike stores and the car park — rather than every corridor. A short zone plan agreed with the landlord before you quote saves arguments with residents later.

ZoneWhy it is coveredSuggested cameraWatch out for
Main entrance (outside)Faces of everyone entering, tailgating, deliveriesMotorised AcuSense LiveGuard turretMask the pavement and houses opposite
Lobby and post boxesParcel theft, post box damage, unknown visitors360° fisheye on the ceilingMask any ground-floor flat door in view
Stairs and corridorsOnly where the risk justifies it: anti-social behaviour, damage, e-scooters left on escape routesSlim ColorVu domeMask every flat door as the view passes it
Bin storeFly-tipping, arson, contractorsColorVu turret or panoramic cameraLow light and condensation; fit the camera inside the store
Bike and scooter storeCycle theft and unauthorised chargingLiveGuard turret with line crossingPair with a fob reader on the store door
Car park and gatesVehicle damage, unauthorised parkingAcuSense bullet, ANPR at the gateKeep views inside the site boundary
Inside flats, through windows, private balconiesNever covered by communal CCTV—Re-aim or mask any camera that sees into a home

Government fire guidance for small blocks adds two design points worth quoting to the landlord: refuse and recycling bins should be kept clear of the building or in a secure store, and mobility scooters, e-bikes and e-scooters should not be stored in the common parts or charged there at all (Home Office: making your small block of flats safe from fire). A camera on the bin store and a fob-controlled bike store support both rules.

Choosing cameras for entrances, lobbies and stores

For most blocks, three camera types cover everything: an AcuSense LiveGuard turret for entrances and stores, a 360° fisheye for the lobby, and a ColorVu dome or turret wherever the lighting is poor. All are standard PoE IP cameras, so one recorder and one cable type does the whole building.

At the main door, a motorised turret lets you frame the face of each person at the entry panel and adjust the zoom from the recorder rather than a ladder. The Hikvision DS-2CD2346G3-IZS2UY/SL is a 4MP AcuSense LiveGuard turret with a motorised varifocal lens, and the DS-2CD2386G2H-IS2U/SL is the 8MP fixed-lens equivalent for wider entrances. LiveGuard cameras add a strobe light and a warning siren that can be triggered by a person crossing a line — useful on a bin store or bike store after midnight, but usually switched off on the main entrance so residents are not startled.

In the lobby, one ceiling fisheye replaces three or four fixed cameras and shows the post boxes, the door and the stairs at once. The Hikvision DS-2CD63C5G1-IVS is a 12MP DeepinView fisheye with a 1.29 mm lens (DS-2CD63C5G1-IVS datasheet), and the recorder can de-warp the image into normal views when footage is reviewed.

For corridors and stairwells, a slim dome is less obtrusive and harder to knock out of position. The HiLook IPC-D149HAA-LU ColorVu dome and the matching HiLook IPC-T249HAA-LU turret are good-value 4MP choices for long runs and bin stores. Outside, the Hikvision DS-2CD2387G2P-LSU/SL panoramic ColorVu camera covers a whole car park or courtyard from one position, the DS-2CD2T46G2H-IS2U/SL LiveGuard bullet watches gates and parking bays, and the Hikvision iDS-TCM403-GIR ANPR camera reads plates at a barrier for residents-only parking. Our Hikvision camera buyer’s guide compares the wider range.

Recording, retention and requests for footage

Record communal cameras on an NVR in a locked cupboard or comms cabinet that only the landlord or agent can open, set a retention period the landlord can justify and make sure footage can be found and exported quickly. A tenant’s request for footage of themselves usually has to be answered within a month.

Size the recorder to the camera count with headroom for one or two more. The Hikvision DS-7608NXI-K1/8P(E) has eight PoE ports and a single drive bay (DS-7608NXI-K1/8P(E) datasheet) and suits a converted house or small block; the DS-7616NXI-K2/16P(E) steps up to 16 PoE cameras for a mid-sized block; and the DS-7716NXI-K4/16P/VPRO adds four drive bays and AcuSeek text search (DS-7716NXI-K4/16P/VPRO datasheet), which helps a managing agent find “person with a bike at the store door” without scrolling through a week of video.

There is no fixed legal retention period for communal CCTV. Around 30 days is common because it is long enough for most incidents to be reported. As a rough guide, a camera recording continuously at 4 Mbps uses about 1.3 TB in 30 days; AcuSense event recording on quiet corridors cuts that considerably. Set retention by days on the recorder, not by “overwrite when full”, so the period stays the one the landlord has written down.

When a resident, an insurer or the police ask for a clip, the agent needs to export it quickly and blur or crop other people where necessary. Our step-by-step guide to exporting CCTV footage from a Hikvision NVR covers USB export, iVMS-4200 and Hik-Connect, and the Hikvision NVR buyer’s guide explains the recorder range.

Video door entry for flats

A block of flats needs a door entry system with one call button or directory entry per flat, a monitor in each flat and a lock release at the main door. Choose IP for new cabling, 2-wire HD where you are reusing old two-core intercom cable, and a multi-button villa station for small conversions.

IP modular (new builds and full rewires). The Hikvision DS-KD8003-IME1(B)/S is the main unit of Hikvision’s KD8 modular door station: a 2MP fisheye camera with IR, a call button, two-lock control, standard PoE and an IP65 rating (Hikvision DS-KD8003-IME1(B) product page). Build the panel up with a DS-KD-DIS display module so visitors can scroll a resident directory, a DS-KD-KP/S keypad for flat numbers and PIN entry, and a DS-KD-M card reader module for residents’ fobs, housed in a DS-KD-ACW3/S three-module surface box. In each flat, a DS-KH6320-WTE1 7-inch indoor station is the workhorse, with the DS-KH8381-WTE1 for higher-spec developments. Residents can also answer on their phones through Hik-Connect, which matters for tenants who are rarely home.

2-wire HD (retrofit on existing cable). Many older blocks have an audio intercom on two-core cable that nobody wants to rip out. The Hikvision DS-KD7003EY-IME2 is a 2-wire HD modular door station with a 2MP camera and two-lock control, powered through the DS-KAD7060EY 2-wire distributor (Hikvision DS-KD7003EY-IME2 product page), with DS-KH7300EY-WTE2 7-inch touchscreen monitors in the flats. Test the old cable before you commit: a damaged pair will fail on 2-wire just as it did on audio.

Small conversions and HMOs. A house split into two to four flats does not need a modular panel. The Hikvision DS-KV8413-WME1 is a four-button metal villa door station, one button per flat, and the new TalkVu DS-KV8114-NWQE1 name-tag station suits a shared HMO front door where tenants want a phone app as well as an indoor screen. Our TalkVu installer guide and Hikvision video intercom guide go deeper on configuration.

BuildingBest systemDoor stationIn each flat
House converted to 2–4 flatsIP villa, one button per flatDS-KV8413-WME1DS-KH6320-WTE1 or app only
Shared-house HMOIP villa with app answeringDS-KV8114-NWQE1One indoor station in the hallway plus tenants’ apps
Purpose-built block, new cablingIP modular with directoryDS-KD8003-IME1(B)/S + DS-KD-DIS + DS-KD-KP/S + DS-KD-MDS-KH6320-WTE1 / DS-KH8381-WTE1
Older block, existing two-core cable2-wire HDDS-KD7003EY-IME2 + DS-KAD7060EYDS-KH7300EY-WTE2

Fob access control and fail-safe locks

Government guidance for small blocks expects access doors to be secured, typically with electronic access control needing a fob to get in and a lever handle or similar to get out, and the electronic locks should be fail-safe so they release if the power to them fails completely (Home Office small blocks guide). That is the brief for every main door, bin store and bike store.

A magnetic lock is fail-safe by design, which is why it is the usual choice on a communal entrance. A typical door uses a Hikvision DS-K1108AMK Mifare reader with keypad on the outside, a DS-K2602T two-door controller (main door plus bin or bike store), a DS-K4H250D magnetic lock on double doors, a DS-K7P03 no-touch exit button and a green DS-K7PEB break-glass on the escape side. Residents carry DS-K7M102-M contactless tags, which the managing agent can cancel the day a fob is lost or a tenant moves out — the single biggest advantage over keys.

Three details catch installers out in flats. Make sure the maglock and door closer still let the door self-close and latch, because a communal door that hangs open fails its fire door check. Agree how the fire and rescue service will get in — a key switch, a code or a drop key — with the fire risk assessor. And keep the lock power supply on its own fused spur with battery standby sized so that a short mains cut does not leave the door open all night. Our Hikvision access control guide covers wiring and controller set-up.

Fire alarms in blocks of flats: stay put vs communal alarm

Most purpose-built blocks are designed for “stay put”: each flat is a fire compartment, so only the flat on fire needs to leave. In those blocks the fire protection is the alarms inside each flat, not a communal fire alarm, and fitting sounders in the common parts can do more harm than good.

The Home Office guide for small blocks is blunt about it: fire alarm systems are not appropriate in the common parts of blocks with enough compartmentation to support stay put, because they contradict the strategy and can draw residents into communal areas. Where smoke detectors open automatic smoke vents in the stairwell, those detectors should not set off bells or sounders either. A communal alarm only becomes necessary if a specialist decides stay put is no longer appropriate (Home Office small blocks guide).

So when a managing agent asks for “a fire alarm in the hallways”, the right first answer is a question: what does the fire risk assessment say about the evacuation strategy? If it is stay put, your work is inside the flats — smoke alarms on every level, a heat alarm in the kitchen and CO alarms where there are fuel-burning appliances. If the assessor has moved the block to simultaneous evacuation, the communal system is designed by a fire specialist, and a wireless EN 54 system such as the Ajax EN54 Fire Hub Jeweller is one way to install it without chasing cables through occupied flats. Our wireless fire alarm systems guide explains how those systems are designed and certified.

Smoke and carbon monoxide alarms in rented flats

In England, every privately or socially rented home must have a smoke alarm on each storey used as living accommodation and a carbon monoxide alarm in any room used as living accommodation that has a fixed combustion appliance, other than a gas cooker (Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022). Landlords must also repair or replace an alarm once they are told it is faulty.

The regulations do not insist on mains-wired alarms, which is where wireless alarms earn their place in single-let flats. The Ajax FireProtect 2 SB (Heat/Smoke/CO) combines smoke, heat and CO sensing in one detector, runs on two sealed lithium batteries with a stated 10-year battery life, carries BSI Kitemarks for smoke, heat and CO alarms and is certified to EN 14604 and EN 50291-1 (Ajax FireProtect 2 SB technical specifications). It is for indoor use only. The FireProtect 2 RB is the same detector with replaceable batteries.

Connected to an Ajax Hub 2 Plus, the detectors interconnect: when one detects a fire, the hub sets off the others within 20 seconds and sends an alert to the Ajax app, according to Ajax’s specification. For a landlord, the app is the real benefit — a low-battery, tamper or fault warning reaches the agent the same day instead of waiting for the next inspection. Keep the flat’s alarms on the flat’s own hub or the landlord’s account; never link flats together into a building-wide alarm in a stay-put block.

Scotland goes further. Since February 2022 every home must have a smoke alarm in the room used most, one in every circulation space on each storey and a heat alarm in each kitchen, all ceiling-mounted and interlinked, plus a CO detector where there is a carbon-fuelled appliance such as a boiler; alarms can be sealed long-life battery or mains-powered, and mains alarms must be fitted by a qualified electrician (Scottish Government: changes to fire safety laws). Interlinked sealed-battery detectors on a hub meet that brief without rewiring a tenanted flat; specify a heat-only detector for the kitchen.

HMO fire alarm requirements by house type

HMO fire detection is set by the council through the licence, usually following LACORS guidance and BS 5839-6, and the grade depends on whether the house is a shared house or bedsits and how many storeys it has. Many councils ask for mains-powered Grade D1 alarms as the minimum.

A large HMO needs a licence in England when it is rented to five or more people from more than one household who share a kitchen, bathroom or toilet (GOV.UK: HMO licence), and many councils license smaller HMOs too. Wandsworth Council’s published HMO fire guidance is a good example of what licence conditions look like (Wandsworth: fire safety guidance in HMO properties):

HMO typeGrade and categoryWhere detection goes
Shared house, up to 2 storeysGrade D1, Category LD2Mains interlinked smoke alarms in hall, landing and lounge; heat alarm in the kitchen
Shared house, 3–4 storeysGrade D1, Category LD2As above, plus smoke alarms in all bedrooms and other risk rooms
Bedsits, up to 2 storeysGrade D1, Category LD1Throughout the escape route and in every room; heat alarms where a bedsit has cooking
Bedsits, 3–4 storeysGrade A, Category LD1Panel-based system with call points at final exits; 65 dB(A) in all parts and 75 dB(A) at bed-heads

The same guidance notes that BS 5839-6:2019 only treats a property as a shared-house HMO for fire purposes if no more than six people share it. Grade D1 means mains-powered alarms with a tamper-proof standby battery, so a battery-only wireless detector does not meet a D1 licence condition on its own. Ajax makes a mains-powered version, the FireProtect 2 AC (Ajax FireProtect 2 AC specifications); otherwise use the council’s required grade for the licensable system and add Ajax detectors for CO, leak and app-based fault reporting. Always work from the licence conditions and the fire risk assessment, not from a generic table — councils differ.

Fire doors: the checks your kit must not break

Fire doors protect the escape route in every block and HMO, and since January 2023 the Responsible Person must give residents fire door information and, in buildings whose top storey is above 11 m, check communal fire doors every three months and use best endeavours to check flat entrance doors every 12 months.

The government’s guidance lists what each check looks for: no damage, intact seals, a gap of no more than 4 mm except at the bottom, and above all an effective self-closing device that shuts the door fully from any angle. It also notes that corridor doors held open on magnetic hold-open devices need smoke detectors that release them (GOV.UK fire door guidance).

For an installer that becomes a short list of rules. Do not drill a fire door for a reader, cable or lock without the door manufacturer’s approved method. Never fit a maglock or closer that stops a fire door self-closing. Do not fit a flat door camera or doorbell that needs a hole through the door. And leave letterboxes, seals and closers as you found them. A camera on the communal corridor can help the agent prove a door was wedged open or a closer was tampered with, but the camera is evidence, not a substitute for the checks.

Leaks, empty flats and void property protection

Water escaping from one flat into another is one of the most expensive and common claims in a block, and empty flats between tenancies attract break-ins and squatters. Both are cheap to protect with wireless sensors on an Ajax hub.

An Ajax LeaksProtect under the boiler, the washing machine and the kitchen sink of each flat alerts the landlord’s app as soon as water reaches the floor, and is the simplest way to stop an upstairs leak turning into two ceilings and an insurance claim. Our LeaksProtect guide covers placement and automatic valve shut-off.

For void flats, the same Hub 2 Plus can run a temporary intruder alarm with door contacts and motion detectors, moved from flat to flat as tenancies change. Our Ajax wireless alarm guide explains detector choice and grading.

Wi-Fi and networks for HMOs and blocks

Tenants in an HMO expect working Wi-Fi in every room, and the landlord’s cameras, door entry and access control need a network the tenants cannot reach. One Reyee gateway with separate VLANs and SSIDs does both.

A Reyee RG-EG105G-P-V3 cloud gateway with built-in PoE suits a converted house, with a Reyee RG-ES226GC-P 24-port PoE switch in a larger block’s comms room. In each HMO bedroom, a wall-plate access point such as the Reyee RG-RAP1261 or RG-AP180 replaces a network socket and gives every tenant strong Wi-Fi 6 without a ceiling AP in a private room. Put cameras, the NVR, door entry and access control on their own VLAN, tenants on an isolated SSID, and manage the whole site from the Reyee cloud app. Our Reyee wall-plate access point guide and Reyee networking buyer’s guide explain the set-up.

Comparison of security kit for a converted house, a licensed HMO and a purpose-built block of flats

Three reference builds: converted house, HMO and purpose-built block

Most multi-occupancy jobs fall into three shapes: a house converted into a handful of flats, a licensed HMO with shared facilities, and a purpose-built block. The table below is a starting point to adapt to each fire risk assessment and licence.

SystemConverted house, 3–4 flatsLicensed HMO, 6 roomsPurpose-built block, 24 flats
CCTVFront door turret, bin store HiLook turret, DS-7608NXI-K1/8P(E)Front door turret, kitchen-hall dome only if the licence and tenants agree, DS-7608NXI-K1/8P(E)Entrance turrets, lobby fisheye, stores, panoramic car park camera, DS-7716NXI-K4/16P/VPRO
Door entryDS-KV8413-WME1 + DS-KH6320-WTE1 per flatDS-KV8114-NWQE1 + app answeringDS-KD8003-IME1(B)/S modular with directory, or 2-wire HD retrofit
AccessFob reader and maglock on the front doorFob front door; thumb-turn room locksDS-K2602T, fob readers on entrance, bin and bike stores
FireAlarms in each flat to the FRA; FireProtect 2 for CO and app alertsLicence grade (often D1 LD2 mains), plus Ajax CO and leak sensorsStay put: alarms inside flats only; communal system only if the FRA requires it
NetworkRG-EG105G-P-V3RG-EG105G-P-V3 + RG-RAP1261 per roomRG-ES226GC-P + gateway, VLANs for CCTV and door entry

Commissioning and handover checklist

A multi-occupancy system is only finished when the landlord or agent can run it without you. Check these before you leave site and leave a copy in the comms cupboard.

  1. Camera list agreed in writing with the landlord, with no camera seeing into a flat, window or private balcony.
  2. Privacy masks set and tested with flat doors open.
  3. Audio recording off on every camera unless documented.
  4. Retention set in days and confirmed after a week of recording.
  5. Named user accounts for the agent; admin password held by the landlord.
  6. A test clip exported and the export steps written down.
  7. Every maglock released on power failure and by the exit button and break-glass; fire service access agreed.
  8. Every fire door you touched still self-closes and latches from any angle.
  9. Smoke, heat and CO alarms tested in each flat, with the results recorded for the tenancy file.
  10. CCTV signs fitted at each entrance naming the operator.
Six-step workflow for securing a block of flats or HMO from survey to handover

Frequently asked questions: block of flats and HMO security

Can a landlord put CCTV in the communal areas of a block of flats?

Yes. It is common and lawful, but data protection law applies: the landlord needs a clear reason, signs, a set retention period, privacy masks over flat doors and a way to give people footage of themselves (ICO).

Can CCTV be fitted inside an HMO?

Only in shared areas such as the entrance hall, and only where the landlord can justify it and the tenants have been told. Never in bedrooms, bathrooms or any room let to a tenant. Many landlords limit HMO cameras to the outside and the front door.

Can a tenant fit a video doorbell on their flat door?

Usually, with the landlord’s permission and without drilling a fire door. If it records the shared corridor, the tenant has to follow the data protection rules for communal spaces, according to the ICO.

Does a block of flats need a fire alarm in the corridors?

Not if it is designed for stay put. Government guidance says communal fire alarms are not appropriate in blocks with adequate compartmentation; protection comes from alarms inside each flat. A communal system is only needed where the fire risk assessment calls for simultaneous evacuation.

What fire alarm does an HMO need?

Whatever the council’s licence conditions say, typically based on LACORS guidance and BS 5839-6. Shared houses are often Grade D1 LD2; bedsit HMOs of three or more storeys can need a Grade A panel system.

Are wireless smoke alarms acceptable in rented flats?

In England, the rented-home rules do not require mains alarms, and Scotland accepts sealed long-life battery alarms if they are interlinked. Licensed HMOs often need mains-powered Grade D1 alarms, so check the licence first.

Can I reuse the old intercom cable when upgrading to video door entry?

Often, yes. Hikvision’s 2-wire HD range runs video over existing two-core cable through a DS-KAD7060EY distributor. Test each pair first, as a damaged pair will still fail.

Should door fobs be cancelled when a tenant leaves?

Yes, on the day they leave. That is the main advantage of fob access over keys: the agent removes the fob in the controller or app, and a lost fob stops working without changing a lock.

Related posts

Ordering

Netview CCTV stocks the Hikvision, HiLook, Ajax and Reyee cameras, recorders, door entry, access control, fire, alarm and networking products in this guide in Leicester, with same-day dispatch on stocked lines. Browse the full range at netviewcctv.co.uk/brands, or contact us through the website for trade pricing.

Quoting a block of flats or an HMO?

Trade pricing, real stock and same-day dispatch on Hikvision, HiLook, Ajax and Reyee — order online at netviewcctv.co.uk.



What's this? Check "Remember Me" to access your shopping cart on this computer even if you are not signed in.